Clean room ISO class 8
Brief description:
- Self-supporting, self-sufficient clean room
- Floor space140m2
- Interior height 4m
- ISO8
Box made of 80 mm sandwich panels (color similar to RAL 9010), supported by steel construction
Floor: Leveled, epoxy resin coated, antistatic (not ESD), color RAL 9002 gloss
Joints: Special clean room joint kit
Combined personnel and material airlock with door locks (no waiting times)
Access ladder and fence on roof
Qualified and certified according to DIN EN ISO 14644, Class 8
Approved & authorized by the Nidwalden Labor Inspectorate, SUVA, and the Federal Office of Civil Aviation
Clean room located in 6371 Stans.
Prior viewing and discussion are possible and desired.
Price upon agreement
Price on request
Description of the
Technical data:
Monoblock Sevenair with max. 10 air changes per hour
Air conditioning and humidification/dehumidification
Central supply air filter at the monoblock outlet
Recirculation type: turbulent mixed ventilation through monoblock extraction in the floor area
Recirculation volume flow: 4,500 m³/h
Air intake via ceiling inlets
Return air system via ring duct to monoblock
Differential pressure relative to the hall: 25 PA
Outside air comes from the hall and returns to the hall via the airlock openings
Outside air volume flow for room overpressure: max. 500m3/h
Outside air treatment: Filtering (filter stage F7) and absorption drying
Separate recirculation system in airlock with tube fan and filter
Adsorption dryer with heat recovery
Maximum cooling load: 8 KW
Humidification via electrode steam humidifier
Maximum ambient humidity: 78.9% relative humidity
Maximum ambient temperature: 30°C (in practice, the system also runs stably at 35°C)
LED cleanroom recessed lights, 750 lux illuminance, dimmable, 4 light zones
Vacuum system on roof. Mink Lumpe Series 40, soundproofed, 70-liter vacuum container
Online monitoring system for the following parameters via cloud system:
o Relative humidity, permanent
o Temperature, permanent
o Pressure difference inside/outside, permanent
o Number of dust particles, manual measurement with Solair 3100 mobile device
Fire protection/alarms:
o Sprinklers, building-side
o Smoke and flame detectors on the ceiling and in the return air duct, building-side
o Siemens fire alarm system, building-side
o Collective alarm on building management system (also for room parameters outside the tolerance range)
The items listed below are currently available in the cleanroom, but are not included in the scope of delivery:
- soil
- sprinkler system
- Siemens fire alarm system
- Device for collective alarm via building management system for night watch
- Solair 3100 mobile particle measuring device
- License for the online monitoring system (however, the system hardware remains in the available control cabinet)